    Configure NPU attributes. Applies to FortiOS Version 7.0.4.

    Create Npu Resource

    Resources are created with functions called constructors. To learn more about declaring and configuring resources, see Resources.

    Constructor syntax

    new Npu(name: string, args?: NpuArgs, opts?: CustomResourceOptions);
    @overload
    def Npu(resource_name: str,
            args: Optional[NpuArgs] = None,
            opts: Optional[ResourceOptions] = None)
    
    @overload
    def Npu(resource_name: str,
            opts: Optional[ResourceOptions] = None,
            capwap_offload: Optional[str] = None,
            dedicated_management_affinity: Optional[str] = None,
            dedicated_management_cpu: Optional[str] = None,
            fastpath: Optional[str] = None,
            get_all_tables: Optional[str] = None,
            ipsec_dec_subengine_mask: Optional[str] = None,
            ipsec_enc_subengine_mask: Optional[str] = None,
            ipsec_inbound_cache: Optional[str] = None,
            ipsec_mtu_override: Optional[str] = None,
            ipsec_over_vlink: Optional[str] = None,
            mcast_session_accounting: Optional[str] = None,
            np6_cps_optimization_mode: Optional[str] = None,
            priority_protocol: Optional[NpuPriorityProtocolArgs] = None,
            rdp_offload: Optional[str] = None,
            session_denied_offload: Optional[str] = None,
            sse_backpressure: Optional[str] = None,
            strip_clear_text_padding: Optional[str] = None,
            strip_esp_padding: Optional[str] = None,
            sw_np_bandwidth: Optional[str] = None,
            uesp_offload: Optional[str] = None,
            vdomparam: Optional[str] = None)
    func NewNpu(ctx *Context, name string, args *NpuArgs, opts ...ResourceOption) (*Npu, error)
    public Npu(string name, NpuArgs? args = null, CustomResourceOptions? opts = null)
    public Npu(String name, NpuArgs args)
    public Npu(String name, NpuArgs args, CustomResourceOptions options)
    
    type: fortios:system:Npu
    properties: # The arguments to resource properties.
    options: # Bag of options to control resource's behavior.
    
    

    Parameters

    name string
    The unique name of the resource.
    args NpuArgs
    The arguments to resource properties.
    opts CustomResourceOptions
    Bag of options to control resource's behavior.
    resource_name str
    The unique name of the resource.
    args NpuArgs
    The arguments to resource properties.
    opts ResourceOptions
    Bag of options to control resource's behavior.
    ctx Context
    Context object for the current deployment.
    name string
    The unique name of the resource.
    args NpuArgs
    The arguments to resource properties.
    opts ResourceOption
    Bag of options to control resource's behavior.
    name string
    The unique name of the resource.
    args NpuArgs
    The arguments to resource properties.
    opts CustomResourceOptions
    Bag of options to control resource's behavior.
    name String
    The unique name of the resource.
    args NpuArgs
    The arguments to resource properties.
    options CustomResourceOptions
    Bag of options to control resource's behavior.

    Constructor example

    The following reference example uses placeholder values for all input properties.

    var npuResource = new Fortios.System.Npu("npuResource", new()
    {
        CapwapOffload = "string",
        DedicatedManagementAffinity = "string",
        DedicatedManagementCpu = "string",
        Fastpath = "string",
        GetAllTables = "string",
        IpsecDecSubengineMask = "string",
        IpsecEncSubengineMask = "string",
        IpsecInboundCache = "string",
        IpsecMtuOverride = "string",
        IpsecOverVlink = "string",
        McastSessionAccounting = "string",
        Np6CpsOptimizationMode = "string",
        PriorityProtocol = new Fortios.System.Inputs.NpuPriorityProtocolArgs
        {
            Bfd = "string",
            Bgp = "string",
            Slbc = "string",
        },
        RdpOffload = "string",
        SessionDeniedOffload = "string",
        SseBackpressure = "string",
        StripClearTextPadding = "string",
        StripEspPadding = "string",
        SwNpBandwidth = "string",
        UespOffload = "string",
        Vdomparam = "string",
    });
    
    example, err := system.NewNpu(ctx, "npuResource", &system.NpuArgs{
    	CapwapOffload:               pulumi.String("string"),
    	DedicatedManagementAffinity: pulumi.String("string"),
    	DedicatedManagementCpu:      pulumi.String("string"),
    	Fastpath:                    pulumi.String("string"),
    	GetAllTables:                pulumi.String("string"),
    	IpsecDecSubengineMask:       pulumi.String("string"),
    	IpsecEncSubengineMask:       pulumi.String("string"),
    	IpsecInboundCache:           pulumi.String("string"),
    	IpsecMtuOverride:            pulumi.String("string"),
    	IpsecOverVlink:              pulumi.String("string"),
    	McastSessionAccounting:      pulumi.String("string"),
    	Np6CpsOptimizationMode:      pulumi.String("string"),
    	PriorityProtocol: &system.NpuPriorityProtocolArgs{
    		Bfd:  pulumi.String("string"),
    		Bgp:  pulumi.String("string"),
    		Slbc: pulumi.String("string"),
    	},
    	RdpOffload:            pulumi.String("string"),
    	SessionDeniedOffload:  pulumi.String("string"),
    	SseBackpressure:       pulumi.String("string"),
    	StripClearTextPadding: pulumi.String("string"),
    	StripEspPadding:       pulumi.String("string"),
    	SwNpBandwidth:         pulumi.String("string"),
    	UespOffload:           pulumi.String("string"),
    	Vdomparam:             pulumi.String("string"),
    })
    
    var npuResource = new Npu("npuResource", NpuArgs.builder()
        .capwapOffload("string")
        .dedicatedManagementAffinity("string")
        .dedicatedManagementCpu("string")
        .fastpath("string")
        .getAllTables("string")
        .ipsecDecSubengineMask("string")
        .ipsecEncSubengineMask("string")
        .ipsecInboundCache("string")
        .ipsecMtuOverride("string")
        .ipsecOverVlink("string")
        .mcastSessionAccounting("string")
        .np6CpsOptimizationMode("string")
        .priorityProtocol(NpuPriorityProtocolArgs.builder()
            .bfd("string")
            .bgp("string")
            .slbc("string")
            .build())
        .rdpOffload("string")
        .sessionDeniedOffload("string")
        .sseBackpressure("string")
        .stripClearTextPadding("string")
        .stripEspPadding("string")
        .swNpBandwidth("string")
        .uespOffload("string")
        .vdomparam("string")
        .build());
    
    npu_resource = fortios.system.Npu("npuResource",
        capwap_offload="string",
        dedicated_management_affinity="string",
        dedicated_management_cpu="string",
        fastpath="string",
        get_all_tables="string",
        ipsec_dec_subengine_mask="string",
        ipsec_enc_subengine_mask="string",
        ipsec_inbound_cache="string",
        ipsec_mtu_override="string",
        ipsec_over_vlink="string",
        mcast_session_accounting="string",
        np6_cps_optimization_mode="string",
        priority_protocol={
            "bfd": "string",
            "bgp": "string",
            "slbc": "string",
        },
        rdp_offload="string",
        session_denied_offload="string",
        sse_backpressure="string",
        strip_clear_text_padding="string",
        strip_esp_padding="string",
        sw_np_bandwidth="string",
        uesp_offload="string",
        vdomparam="string")
    
    const npuResource = new fortios.system.Npu("npuResource", {
        capwapOffload: "string",
        dedicatedManagementAffinity: "string",
        dedicatedManagementCpu: "string",
        fastpath: "string",
        getAllTables: "string",
        ipsecDecSubengineMask: "string",
        ipsecEncSubengineMask: "string",
        ipsecInboundCache: "string",
        ipsecMtuOverride: "string",
        ipsecOverVlink: "string",
        mcastSessionAccounting: "string",
        np6CpsOptimizationMode: "string",
        priorityProtocol: {
            bfd: "string",
            bgp: "string",
            slbc: "string",
        },
        rdpOffload: "string",
        sessionDeniedOffload: "string",
        sseBackpressure: "string",
        stripClearTextPadding: "string",
        stripEspPadding: "string",
        swNpBandwidth: "string",
        uespOffload: "string",
        vdomparam: "string",
    });
    
    type: fortios:system:Npu
    properties:
        capwapOffload: string
        dedicatedManagementAffinity: string
        dedicatedManagementCpu: string
        fastpath: string
        getAllTables: string
        ipsecDecSubengineMask: string
        ipsecEncSubengineMask: string
        ipsecInboundCache: string
        ipsecMtuOverride: string
        ipsecOverVlink: string
        mcastSessionAccounting: string
        np6CpsOptimizationMode: string
        priorityProtocol:
            bfd: string
            bgp: string
            slbc: string
        rdpOffload: string
        sessionDeniedOffload: string
        sseBackpressure: string
        stripClearTextPadding: string
        stripEspPadding: string
        swNpBandwidth: string
        uespOffload: string
        vdomparam: string
    

    Npu Resource Properties

    To learn more about resource properties and how to use them, see Inputs and Outputs in the Architecture and Concepts docs.

    Inputs

    In Python, inputs that are objects can be passed either as argument classes or as dictionary literals.

    The Npu resource accepts the following input properties:

    CapwapOffload string
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    DedicatedManagementAffinity string
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    DedicatedManagementCpu string
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    Fastpath string
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    GetAllTables string
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    IpsecDecSubengineMask string
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    IpsecEncSubengineMask string
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    IpsecInboundCache string
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    IpsecMtuOverride string
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    IpsecOverVlink string
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    McastSessionAccounting string
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    Np6CpsOptimizationMode string
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    PriorityProtocol Pulumiverse.Fortios.System.Inputs.NpuPriorityProtocol
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    RdpOffload string
    Enable/disable rdp offload. Valid values: enable, disable.
    SessionDeniedOffload string
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    SseBackpressure string
    Enable/disable sse backpressure. Valid values: enable, disable.
    StripClearTextPadding string
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    StripEspPadding string
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    SwNpBandwidth string
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    UespOffload string
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    Vdomparam string
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    CapwapOffload string
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    DedicatedManagementAffinity string
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    DedicatedManagementCpu string
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    Fastpath string
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    GetAllTables string
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    IpsecDecSubengineMask string
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    IpsecEncSubengineMask string
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    IpsecInboundCache string
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    IpsecMtuOverride string
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    IpsecOverVlink string
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    McastSessionAccounting string
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    Np6CpsOptimizationMode string
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    PriorityProtocol NpuPriorityProtocolArgs
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    RdpOffload string
    Enable/disable rdp offload. Valid values: enable, disable.
    SessionDeniedOffload string
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    SseBackpressure string
    Enable/disable sse backpressure. Valid values: enable, disable.
    StripClearTextPadding string
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    StripEspPadding string
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    SwNpBandwidth string
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    UespOffload string
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    Vdomparam string
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    capwapOffload String
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    dedicatedManagementAffinity String
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    dedicatedManagementCpu String
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    fastpath String
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    getAllTables String
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    ipsecDecSubengineMask String
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecEncSubengineMask String
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecInboundCache String
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    ipsecMtuOverride String
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    ipsecOverVlink String
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    mcastSessionAccounting String
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    np6CpsOptimizationMode String
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    priorityProtocol NpuPriorityProtocol
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    rdpOffload String
    Enable/disable rdp offload. Valid values: enable, disable.
    sessionDeniedOffload String
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    sseBackpressure String
    Enable/disable sse backpressure. Valid values: enable, disable.
    stripClearTextPadding String
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    stripEspPadding String
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    swNpBandwidth String
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    uespOffload String
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    vdomparam String
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    capwapOffload string
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    dedicatedManagementAffinity string
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    dedicatedManagementCpu string
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    fastpath string
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    getAllTables string
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    ipsecDecSubengineMask string
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecEncSubengineMask string
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecInboundCache string
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    ipsecMtuOverride string
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    ipsecOverVlink string
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    mcastSessionAccounting string
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    np6CpsOptimizationMode string
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    priorityProtocol NpuPriorityProtocol
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    rdpOffload string
    Enable/disable rdp offload. Valid values: enable, disable.
    sessionDeniedOffload string
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    sseBackpressure string
    Enable/disable sse backpressure. Valid values: enable, disable.
    stripClearTextPadding string
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    stripEspPadding string
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    swNpBandwidth string
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    uespOffload string
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    vdomparam string
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    capwap_offload str
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    dedicated_management_affinity str
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    dedicated_management_cpu str
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    fastpath str
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    get_all_tables str
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    ipsec_dec_subengine_mask str
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    ipsec_enc_subengine_mask str
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    ipsec_inbound_cache str
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    ipsec_mtu_override str
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    ipsec_over_vlink str
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    mcast_session_accounting str
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    np6_cps_optimization_mode str
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    priority_protocol NpuPriorityProtocolArgs
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    rdp_offload str
    Enable/disable rdp offload. Valid values: enable, disable.
    session_denied_offload str
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    sse_backpressure str
    Enable/disable sse backpressure. Valid values: enable, disable.
    strip_clear_text_padding str
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    strip_esp_padding str
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    sw_np_bandwidth str
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    uesp_offload str
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    vdomparam str
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    capwapOffload String
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    dedicatedManagementAffinity String
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    dedicatedManagementCpu String
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    fastpath String
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    getAllTables String
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    ipsecDecSubengineMask String
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecEncSubengineMask String
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecInboundCache String
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    ipsecMtuOverride String
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    ipsecOverVlink String
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    mcastSessionAccounting String
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    np6CpsOptimizationMode String
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    priorityProtocol Property Map
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    rdpOffload String
    Enable/disable rdp offload. Valid values: enable, disable.
    sessionDeniedOffload String
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    sseBackpressure String
    Enable/disable sse backpressure. Valid values: enable, disable.
    stripClearTextPadding String
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    stripEspPadding String
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    swNpBandwidth String
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    uespOffload String
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    vdomparam String
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.

    Outputs

    All input properties are implicitly available as output properties. Additionally, the Npu resource produces the following output properties:

    Id string
    The provider-assigned unique ID for this managed resource.
    Id string
    The provider-assigned unique ID for this managed resource.
    id String
    The provider-assigned unique ID for this managed resource.
    id string
    The provider-assigned unique ID for this managed resource.
    id str
    The provider-assigned unique ID for this managed resource.
    id String
    The provider-assigned unique ID for this managed resource.

    Look up Existing Npu Resource

    Get an existing Npu resource’s state with the given name, ID, and optional extra properties used to qualify the lookup.

    public static get(name: string, id: Input<ID>, state?: NpuState, opts?: CustomResourceOptions): Npu
    @staticmethod
    def get(resource_name: str,
            id: str,
            opts: Optional[ResourceOptions] = None,
            capwap_offload: Optional[str] = None,
            dedicated_management_affinity: Optional[str] = None,
            dedicated_management_cpu: Optional[str] = None,
            fastpath: Optional[str] = None,
            get_all_tables: Optional[str] = None,
            ipsec_dec_subengine_mask: Optional[str] = None,
            ipsec_enc_subengine_mask: Optional[str] = None,
            ipsec_inbound_cache: Optional[str] = None,
            ipsec_mtu_override: Optional[str] = None,
            ipsec_over_vlink: Optional[str] = None,
            mcast_session_accounting: Optional[str] = None,
            np6_cps_optimization_mode: Optional[str] = None,
            priority_protocol: Optional[NpuPriorityProtocolArgs] = None,
            rdp_offload: Optional[str] = None,
            session_denied_offload: Optional[str] = None,
            sse_backpressure: Optional[str] = None,
            strip_clear_text_padding: Optional[str] = None,
            strip_esp_padding: Optional[str] = None,
            sw_np_bandwidth: Optional[str] = None,
            uesp_offload: Optional[str] = None,
            vdomparam: Optional[str] = None) -> Npu
    func GetNpu(ctx *Context, name string, id IDInput, state *NpuState, opts ...ResourceOption) (*Npu, error)
    public static Npu Get(string name, Input<string> id, NpuState? state, CustomResourceOptions? opts = null)
    public static Npu get(String name, Output<String> id, NpuState state, CustomResourceOptions options)
    Resource lookup is not supported in YAML
    name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    state
    Any extra arguments used during the lookup.
    opts
    A bag of options that control this resource's behavior.
    resource_name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    state
    Any extra arguments used during the lookup.
    opts
    A bag of options that control this resource's behavior.
    name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    state
    Any extra arguments used during the lookup.
    opts
    A bag of options that control this resource's behavior.
    name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    state
    Any extra arguments used during the lookup.
    opts
    A bag of options that control this resource's behavior.
    The following state arguments are supported:
    CapwapOffload string
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    DedicatedManagementAffinity string
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    DedicatedManagementCpu string
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    Fastpath string
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    GetAllTables string
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    IpsecDecSubengineMask string
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    IpsecEncSubengineMask string
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    IpsecInboundCache string
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    IpsecMtuOverride string
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    IpsecOverVlink string
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    McastSessionAccounting string
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    Np6CpsOptimizationMode string
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    PriorityProtocol Pulumiverse.Fortios.System.Inputs.NpuPriorityProtocol
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    RdpOffload string
    Enable/disable rdp offload. Valid values: enable, disable.
    SessionDeniedOffload string
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    SseBackpressure string
    Enable/disable sse backpressure. Valid values: enable, disable.
    StripClearTextPadding string
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    StripEspPadding string
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    SwNpBandwidth string
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    UespOffload string
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    Vdomparam string
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    CapwapOffload string
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    DedicatedManagementAffinity string
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    DedicatedManagementCpu string
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    Fastpath string
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    GetAllTables string
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    IpsecDecSubengineMask string
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    IpsecEncSubengineMask string
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    IpsecInboundCache string
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    IpsecMtuOverride string
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    IpsecOverVlink string
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    McastSessionAccounting string
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    Np6CpsOptimizationMode string
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    PriorityProtocol NpuPriorityProtocolArgs
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    RdpOffload string
    Enable/disable rdp offload. Valid values: enable, disable.
    SessionDeniedOffload string
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    SseBackpressure string
    Enable/disable sse backpressure. Valid values: enable, disable.
    StripClearTextPadding string
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    StripEspPadding string
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    SwNpBandwidth string
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    UespOffload string
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    Vdomparam string
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    capwapOffload String
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    dedicatedManagementAffinity String
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    dedicatedManagementCpu String
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    fastpath String
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    getAllTables String
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    ipsecDecSubengineMask String
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecEncSubengineMask String
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecInboundCache String
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    ipsecMtuOverride String
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    ipsecOverVlink String
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    mcastSessionAccounting String
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    np6CpsOptimizationMode String
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    priorityProtocol NpuPriorityProtocol
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    rdpOffload String
    Enable/disable rdp offload. Valid values: enable, disable.
    sessionDeniedOffload String
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    sseBackpressure String
    Enable/disable sse backpressure. Valid values: enable, disable.
    stripClearTextPadding String
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    stripEspPadding String
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    swNpBandwidth String
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    uespOffload String
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    vdomparam String
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    capwapOffload string
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    dedicatedManagementAffinity string
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    dedicatedManagementCpu string
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    fastpath string
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    getAllTables string
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    ipsecDecSubengineMask string
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecEncSubengineMask string
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecInboundCache string
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    ipsecMtuOverride string
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    ipsecOverVlink string
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    mcastSessionAccounting string
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    np6CpsOptimizationMode string
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    priorityProtocol NpuPriorityProtocol
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    rdpOffload string
    Enable/disable rdp offload. Valid values: enable, disable.
    sessionDeniedOffload string
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    sseBackpressure string
    Enable/disable sse backpressure. Valid values: enable, disable.
    stripClearTextPadding string
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    stripEspPadding string
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    swNpBandwidth string
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    uespOffload string
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    vdomparam string
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    capwap_offload str
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    dedicated_management_affinity str
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    dedicated_management_cpu str
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    fastpath str
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    get_all_tables str
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    ipsec_dec_subengine_mask str
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    ipsec_enc_subengine_mask str
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    ipsec_inbound_cache str
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    ipsec_mtu_override str
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    ipsec_over_vlink str
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    mcast_session_accounting str
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    np6_cps_optimization_mode str
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    priority_protocol NpuPriorityProtocolArgs
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    rdp_offload str
    Enable/disable rdp offload. Valid values: enable, disable.
    session_denied_offload str
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    sse_backpressure str
    Enable/disable sse backpressure. Valid values: enable, disable.
    strip_clear_text_padding str
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    strip_esp_padding str
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    sw_np_bandwidth str
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    uesp_offload str
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    vdomparam str
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.
    capwapOffload String
    Enable/disable offloading managed FortiAP and FortiLink CAPWAP sessions. Valid values: enable, disable.
    dedicatedManagementAffinity String
    Affinity setting for management deamons (hexadecimal value up to 256 bits in the format of xxxxxxxxxxxxxxxx).
    dedicatedManagementCpu String
    Enable to dedicate one CPU for GUI and CLI connections when NPs are busy. Valid values: enable, disable.
    fastpath String
    Enable/disable NP6 offloading (also called fast path). Valid values: disable, enable.
    getAllTables String
    Get all sub-tables including unconfigured tables. Do not set this variable to true if you configure sub-table in another resource, otherwise, conflicts and overwrite will occur. Options: [ false, true ]. false: Default value, do not get unconfigured tables; true: get all tables including unconfigured tables.
    ipsecDecSubengineMask String
    IPsec decryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecEncSubengineMask String
    IPsec encryption subengine mask (0x1 - 0xff, default 0xff).
    ipsecInboundCache String
    Enable/disable IPsec inbound cache for anti-replay. Valid values: enable, disable.
    ipsecMtuOverride String
    Enable/disable NP6 IPsec MTU override. Valid values: disable, enable.
    ipsecOverVlink String
    Enable/disable IPSEC over vlink. Valid values: enable, disable.
    mcastSessionAccounting String
    Enable/disable traffic accounting for each multicast session through TAE counter. Valid values: tpe-based, session-based, disable.
    np6CpsOptimizationMode String
    Enable/disable NP6 connection per second (CPS) optimization mode. Valid values: enable, disable.
    priorityProtocol Property Map
    Configure NPU priority protocol. The structure of priority_protocol block is documented below.
    rdpOffload String
    Enable/disable rdp offload. Valid values: enable, disable.
    sessionDeniedOffload String
    Enable/disable offloading of denied sessions. Requires ses-denied-traffic to be set. Valid values: disable, enable.
    sseBackpressure String
    Enable/disable sse backpressure. Valid values: enable, disable.
    stripClearTextPadding String
    Enable/disable stripping clear text padding. Valid values: enable, disable.
    stripEspPadding String
    Enable/disable stripping ESP padding. Valid values: enable, disable.
    swNpBandwidth String
    Bandwidth from switch to NP. Valid values: 0G, 2G, 4G, 5G, 6G.
    uespOffload String
    Enable/disable UDP-encapsulated ESP offload (default = disable). Valid values: enable, disable.
    vdomparam String
    Specifies the vdom to which the resource will be applied when the FortiGate unit is running in VDOM mode. Only one vdom can be specified. If you want to inherit the vdom configuration of the provider, please do not set this parameter.

    Supporting Types

    NpuPriorityProtocol, NpuPriorityProtocolArgs

    Bfd string
    Enable/disable NPU BFD priority protocol. Valid values: enable, disable.
    Bgp string
    Enable/disable NPU BGP priority protocol. Valid values: enable, disable.
    Slbc string
    Enable/disable NPU SLBC priority protocol. Valid values: enable, disable.
    Bfd string
    Enable/disable NPU BFD priority protocol. Valid values: enable, disable.
    Bgp string
    Enable/disable NPU BGP priority protocol. Valid values: enable, disable.
    Slbc string
    Enable/disable NPU SLBC priority protocol. Valid values: enable, disable.
    bfd String
    Enable/disable NPU BFD priority protocol. Valid values: enable, disable.
    bgp String
    Enable/disable NPU BGP priority protocol. Valid values: enable, disable.
    slbc String
    Enable/disable NPU SLBC priority protocol. Valid values: enable, disable.
    bfd string
    Enable/disable NPU BFD priority protocol. Valid values: enable, disable.
    bgp string
    Enable/disable NPU BGP priority protocol. Valid values: enable, disable.
    slbc string
    Enable/disable NPU SLBC priority protocol. Valid values: enable, disable.
    bfd str
    Enable/disable NPU BFD priority protocol. Valid values: enable, disable.
    bgp str
    Enable/disable NPU BGP priority protocol. Valid values: enable, disable.
    slbc str
    Enable/disable NPU SLBC priority protocol. Valid values: enable, disable.
    bfd String
    Enable/disable NPU BFD priority protocol. Valid values: enable, disable.
    bgp String
    Enable/disable NPU BGP priority protocol. Valid values: enable, disable.
    slbc String
    Enable/disable NPU SLBC priority protocol. Valid values: enable, disable.

    Import

    System Npu can be imported using any of these accepted formats:

    $ pulumi import fortios:system/npu:Npu labelname SystemNpu
    

    If you do not want to import arguments of block:

    $ export “FORTIOS_IMPORT_TABLE”=“false”

    $ pulumi import fortios:system/npu:Npu labelname SystemNpu
    

    $ unset “FORTIOS_IMPORT_TABLE”

    To learn more about importing existing cloud resources, see Importing resources.

    Package Details

    Repository
    fortios pulumiverse/pulumi-fortios
    License
    Apache-2.0
    Notes
    This Pulumi package is based on the fortios Terraform Provider.
    fortios logo
    Fortios v0.0.6 published on Tuesday, Jul 9, 2024 by pulumiverse