equinix.metal.VirtualCircuit

Explore with Pulumi AI

equinix logo
Equinix v0.19.0 published on Thursday, Oct 24, 2024 by Equinix

    Use this resource to associate VLAN with a Dedicated Port from Equinix Fabric - software-defined interconnections.

    See the Virtual Routing and Forwarding documentation for product details and API reference material.

    Example Usage

    using System.Collections.Generic;
    using System.Linq;
    using Pulumi;
    using Equinix = Pulumi.Equinix;
    
    return await Deployment.RunAsync(() => 
    {
        var projectId = "52000fb2-ee46-4673-93a8-de2c2bdba33c";
    
        var connId = "73f12f29-3e19-43a0-8e90-ae81580db1e0";
    
        var test = Equinix.Metal.GetInterconnection.Invoke(new()
        {
            ConnectionId = connId,
        });
    
        var testVlan = new Equinix.Metal.Vlan("testVlan", new()
        {
            ProjectId = projectId,
            Metro = test.Apply(getInterconnectionResult => getInterconnectionResult.Metro),
        });
    
        var testVirtualCircuit = new Equinix.Metal.VirtualCircuit("testVirtualCircuit", new()
        {
            ConnectionId = connId,
            ProjectId = projectId,
            PortId = test.Apply(getInterconnectionResult => getInterconnectionResult.Ports[0]?.Id),
            VlanId = testVlan.Id,
            NniVlan = 1056,
        });
    
    });
    
    package main
    
    import (
    	"github.com/equinix/pulumi-equinix/sdk/go/equinix/metal"
    	"github.com/pulumi/pulumi/sdk/v3/go/pulumi"
    )
    
    func main() {
    	pulumi.Run(func(ctx *pulumi.Context) error {
    		projectId := "52000fb2-ee46-4673-93a8-de2c2bdba33c"
    		connId := "73f12f29-3e19-43a0-8e90-ae81580db1e0"
    		test, err := metal.LookupInterconnection(ctx, &metal.LookupInterconnectionArgs{
    			ConnectionId: connId,
    		}, nil)
    		if err != nil {
    			return err
    		}
    		testVlan, err := metal.NewVlan(ctx, "testVlan", &metal.VlanArgs{
    			ProjectId: pulumi.String(projectId),
    			Metro:     pulumi.String(test.Metro),
    		})
    		if err != nil {
    			return err
    		}
    		_, err = metal.NewVirtualCircuit(ctx, "testVirtualCircuit", &metal.VirtualCircuitArgs{
    			ConnectionId: pulumi.String(connId),
    			ProjectId:    pulumi.String(projectId),
    			PortId:       pulumi.String(test.Ports[0].Id),
    			VlanId:       testVlan.ID(),
    			NniVlan:      pulumi.Int(1056),
    		})
    		if err != nil {
    			return err
    		}
    		return nil
    	})
    }
    
    package generated_program;
    
    import com.pulumi.Context;
    import com.pulumi.Pulumi;
    import com.pulumi.core.Output;
    import com.pulumi.equinix.metal.MetalFunctions;
    import com.pulumi.equinix.metal.inputs.GetInterconnectionArgs;
    import com.pulumi.equinix.metal.Vlan;
    import com.pulumi.equinix.metal.VlanArgs;
    import com.pulumi.equinix.metal.VirtualCircuit;
    import com.pulumi.equinix.metal.VirtualCircuitArgs;
    import java.util.List;
    import java.util.ArrayList;
    import java.util.Map;
    import java.io.File;
    import java.nio.file.Files;
    import java.nio.file.Paths;
    
    public class App {
        public static void main(String[] args) {
            Pulumi.run(App::stack);
        }
    
        public static void stack(Context ctx) {
            final var projectId = "52000fb2-ee46-4673-93a8-de2c2bdba33c";
    
            final var connId = "73f12f29-3e19-43a0-8e90-ae81580db1e0";
    
            final var test = MetalFunctions.getInterconnection(GetInterconnectionArgs.builder()
                .connectionId(connId)
                .build());
    
            var testVlan = new Vlan("testVlan", VlanArgs.builder()
                .projectId(projectId)
                .metro(test.applyValue(getInterconnectionResult -> getInterconnectionResult.metro()))
                .build());
    
            var testVirtualCircuit = new VirtualCircuit("testVirtualCircuit", VirtualCircuitArgs.builder()
                .connectionId(connId)
                .projectId(projectId)
                .portId(test.applyValue(getInterconnectionResult -> getInterconnectionResult.ports()[0].id()))
                .vlanId(testVlan.id())
                .nniVlan(1056)
                .build());
    
        }
    }
    
    import pulumi
    import pulumi_equinix as equinix
    
    project_id = "52000fb2-ee46-4673-93a8-de2c2bdba33c"
    conn_id = "73f12f29-3e19-43a0-8e90-ae81580db1e0"
    test = equinix.metal.get_interconnection_output(connection_id=conn_id)
    test_vlan = equinix.metal.Vlan("testVlan",
        project_id=project_id,
        metro=test.metro)
    test_virtual_circuit = equinix.metal.VirtualCircuit("testVirtualCircuit",
        connection_id=conn_id,
        project_id=project_id,
        port_id=test.ports[0].id,
        vlan_id=test_vlan.id,
        nni_vlan=1056)
    
    import * as pulumi from "@pulumi/pulumi";
    import * as equinix from "@equinix-labs/pulumi-equinix";
    import * as equinix from "@pulumi/equinix";
    
    const projectId = "52000fb2-ee46-4673-93a8-de2c2bdba33c";
    const connId = "73f12f29-3e19-43a0-8e90-ae81580db1e0";
    const test = equinix.metal.getInterconnectionOutput({
        connectionId: connId,
    });
    const testVlan = new equinix.metal.Vlan("testVlan", {
        projectId: projectId,
        metro: test.apply(test => test.metro),
    });
    const testVirtualCircuit = new equinix.metal.VirtualCircuit("testVirtualCircuit", {
        connectionId: connId,
        projectId: projectId,
        portId: test.apply(test => test.ports?.[0]?.id),
        vlanId: testVlan.id,
        nniVlan: 1056,
    });
    
    resources:
      testVlan:
        type: equinix:metal:Vlan
        name: test
        properties:
          projectId: ${projectId}
          metro: ${test.metro}
      testVirtualCircuit:
        type: equinix:metal:VirtualCircuit
        name: test
        properties:
          connectionId: ${connId}
          projectId: ${projectId}
          portId: ${test.ports[0].id}
          vlanId: ${testVlan.id}
          nniVlan: 1056
    variables:
      projectId: 52000fb2-ee46-4673-93a8-de2c2bdba33c
      connId: 73f12f29-3e19-43a0-8e90-ae81580db1e0
      test:
        fn::invoke:
          Function: equinix:metal:getInterconnection
          Arguments:
            connectionId: ${connId}
    

    Create VirtualCircuit Resource

    Resources are created with functions called constructors. To learn more about declaring and configuring resources, see Resources.

    Constructor syntax

    new VirtualCircuit(name: string, args: VirtualCircuitArgs, opts?: CustomResourceOptions);
    @overload
    def VirtualCircuit(resource_name: str,
                       args: VirtualCircuitArgs,
                       opts: Optional[ResourceOptions] = None)
    
    @overload
    def VirtualCircuit(resource_name: str,
                       opts: Optional[ResourceOptions] = None,
                       port_id: Optional[str] = None,
                       project_id: Optional[str] = None,
                       nni_vlan: Optional[int] = None,
                       customer_ip: Optional[str] = None,
                       md5: Optional[str] = None,
                       metal_ip: Optional[str] = None,
                       metal_ipv6: Optional[str] = None,
                       name: Optional[str] = None,
                       connection_id: Optional[str] = None,
                       peer_asn: Optional[int] = None,
                       customer_ipv6: Optional[str] = None,
                       description: Optional[str] = None,
                       speed: Optional[str] = None,
                       subnet: Optional[str] = None,
                       subnet_ipv6: Optional[str] = None,
                       tags: Optional[Sequence[str]] = None,
                       virtual_circuit_id: Optional[str] = None,
                       vlan_id: Optional[str] = None,
                       vrf_id: Optional[str] = None)
    func NewVirtualCircuit(ctx *Context, name string, args VirtualCircuitArgs, opts ...ResourceOption) (*VirtualCircuit, error)
    public VirtualCircuit(string name, VirtualCircuitArgs args, CustomResourceOptions? opts = null)
    public VirtualCircuit(String name, VirtualCircuitArgs args)
    public VirtualCircuit(String name, VirtualCircuitArgs args, CustomResourceOptions options)
    
    type: equinix:metal:VirtualCircuit
    properties: # The arguments to resource properties.
    options: # Bag of options to control resource's behavior.
    
    

    Parameters

    name string
    The unique name of the resource.
    args VirtualCircuitArgs
    The arguments to resource properties.
    opts CustomResourceOptions
    Bag of options to control resource's behavior.
    resource_name str
    The unique name of the resource.
    args VirtualCircuitArgs
    The arguments to resource properties.
    opts ResourceOptions
    Bag of options to control resource's behavior.
    ctx Context
    Context object for the current deployment.
    name string
    The unique name of the resource.
    args VirtualCircuitArgs
    The arguments to resource properties.
    opts ResourceOption
    Bag of options to control resource's behavior.
    name string
    The unique name of the resource.
    args VirtualCircuitArgs
    The arguments to resource properties.
    opts CustomResourceOptions
    Bag of options to control resource's behavior.
    name String
    The unique name of the resource.
    args VirtualCircuitArgs
    The arguments to resource properties.
    options CustomResourceOptions
    Bag of options to control resource's behavior.

    Constructor example

    The following reference example uses placeholder values for all input properties.

    var virtualCircuitResource = new Equinix.Metal.VirtualCircuit("virtualCircuitResource", new()
    {
        PortId = "string",
        ProjectId = "string",
        NniVlan = 0,
        CustomerIp = "string",
        Md5 = "string",
        MetalIp = "string",
        MetalIpv6 = "string",
        Name = "string",
        ConnectionId = "string",
        PeerAsn = 0,
        CustomerIpv6 = "string",
        Description = "string",
        Speed = "string",
        Subnet = "string",
        SubnetIpv6 = "string",
        Tags = new[]
        {
            "string",
        },
        VirtualCircuitId = "string",
        VlanId = "string",
        VrfId = "string",
    });
    
    example, err := metal.NewVirtualCircuit(ctx, "virtualCircuitResource", &metal.VirtualCircuitArgs{
    	PortId:       pulumi.String("string"),
    	ProjectId:    pulumi.String("string"),
    	NniVlan:      pulumi.Int(0),
    	CustomerIp:   pulumi.String("string"),
    	Md5:          pulumi.String("string"),
    	MetalIp:      pulumi.String("string"),
    	MetalIpv6:    pulumi.String("string"),
    	Name:         pulumi.String("string"),
    	ConnectionId: pulumi.String("string"),
    	PeerAsn:      pulumi.Int(0),
    	CustomerIpv6: pulumi.String("string"),
    	Description:  pulumi.String("string"),
    	Speed:        pulumi.String("string"),
    	Subnet:       pulumi.String("string"),
    	SubnetIpv6:   pulumi.String("string"),
    	Tags: pulumi.StringArray{
    		pulumi.String("string"),
    	},
    	VirtualCircuitId: pulumi.String("string"),
    	VlanId:           pulumi.String("string"),
    	VrfId:            pulumi.String("string"),
    })
    
    var virtualCircuitResource = new VirtualCircuit("virtualCircuitResource", VirtualCircuitArgs.builder()
        .portId("string")
        .projectId("string")
        .nniVlan(0)
        .customerIp("string")
        .md5("string")
        .metalIp("string")
        .metalIpv6("string")
        .name("string")
        .connectionId("string")
        .peerAsn(0)
        .customerIpv6("string")
        .description("string")
        .speed("string")
        .subnet("string")
        .subnetIpv6("string")
        .tags("string")
        .virtualCircuitId("string")
        .vlanId("string")
        .vrfId("string")
        .build());
    
    virtual_circuit_resource = equinix.metal.VirtualCircuit("virtualCircuitResource",
        port_id="string",
        project_id="string",
        nni_vlan=0,
        customer_ip="string",
        md5="string",
        metal_ip="string",
        metal_ipv6="string",
        name="string",
        connection_id="string",
        peer_asn=0,
        customer_ipv6="string",
        description="string",
        speed="string",
        subnet="string",
        subnet_ipv6="string",
        tags=["string"],
        virtual_circuit_id="string",
        vlan_id="string",
        vrf_id="string")
    
    const virtualCircuitResource = new equinix.metal.VirtualCircuit("virtualCircuitResource", {
        portId: "string",
        projectId: "string",
        nniVlan: 0,
        customerIp: "string",
        md5: "string",
        metalIp: "string",
        metalIpv6: "string",
        name: "string",
        connectionId: "string",
        peerAsn: 0,
        customerIpv6: "string",
        description: "string",
        speed: "string",
        subnet: "string",
        subnetIpv6: "string",
        tags: ["string"],
        virtualCircuitId: "string",
        vlanId: "string",
        vrfId: "string",
    });
    
    type: equinix:metal:VirtualCircuit
    properties:
        connectionId: string
        customerIp: string
        customerIpv6: string
        description: string
        md5: string
        metalIp: string
        metalIpv6: string
        name: string
        nniVlan: 0
        peerAsn: 0
        portId: string
        projectId: string
        speed: string
        subnet: string
        subnetIpv6: string
        tags:
            - string
        virtualCircuitId: string
        vlanId: string
        vrfId: string
    

    VirtualCircuit Resource Properties

    To learn more about resource properties and how to use them, see Inputs and Outputs in the Architecture and Concepts docs.

    Inputs

    In Python, inputs that are objects can be passed either as argument classes or as dictionary literals.

    The VirtualCircuit resource accepts the following input properties:

    PortId string
    UUID of the Connection Port where the VC is scoped to
    ProjectId string
    UUID of the Project where the VC is scoped to
    ConnectionId string
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    CustomerIp string
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    CustomerIpv6 string
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    Description string
    Description of the Virtual Circuit resource
    Md5 string
    The password that can be set for the VRF BGP peer
    MetalIp string
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    MetalIpv6 string
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    Name string
    Name of the Virtual Circuit resource
    NniVlan int
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    PeerAsn int
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    Speed string
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    Subnet string
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    SubnetIpv6 string
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    Tags List<string>
    Tags attached to the virtual circuit
    VirtualCircuitId string
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    VlanId string
    UUID of the VLAN to associate
    VrfId string
    UUID of the VRF to associate
    PortId string
    UUID of the Connection Port where the VC is scoped to
    ProjectId string
    UUID of the Project where the VC is scoped to
    ConnectionId string
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    CustomerIp string
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    CustomerIpv6 string
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    Description string
    Description of the Virtual Circuit resource
    Md5 string
    The password that can be set for the VRF BGP peer
    MetalIp string
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    MetalIpv6 string
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    Name string
    Name of the Virtual Circuit resource
    NniVlan int
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    PeerAsn int
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    Speed string
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    Subnet string
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    SubnetIpv6 string
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    Tags []string
    Tags attached to the virtual circuit
    VirtualCircuitId string
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    VlanId string
    UUID of the VLAN to associate
    VrfId string
    UUID of the VRF to associate
    portId String
    UUID of the Connection Port where the VC is scoped to
    projectId String
    UUID of the Project where the VC is scoped to
    connectionId String
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    customerIp String
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    customerIpv6 String
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    description String
    Description of the Virtual Circuit resource
    md5 String
    The password that can be set for the VRF BGP peer
    metalIp String
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    metalIpv6 String
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    name String
    Name of the Virtual Circuit resource
    nniVlan Integer
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    peerAsn Integer
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    speed String
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    subnet String
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    subnetIpv6 String
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    tags List<String>
    Tags attached to the virtual circuit
    virtualCircuitId String
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    vlanId String
    UUID of the VLAN to associate
    vrfId String
    UUID of the VRF to associate
    portId string
    UUID of the Connection Port where the VC is scoped to
    projectId string
    UUID of the Project where the VC is scoped to
    connectionId string
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    customerIp string
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    customerIpv6 string
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    description string
    Description of the Virtual Circuit resource
    md5 string
    The password that can be set for the VRF BGP peer
    metalIp string
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    metalIpv6 string
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    name string
    Name of the Virtual Circuit resource
    nniVlan number
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    peerAsn number
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    speed string
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    subnet string
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    subnetIpv6 string
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    tags string[]
    Tags attached to the virtual circuit
    virtualCircuitId string
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    vlanId string
    UUID of the VLAN to associate
    vrfId string
    UUID of the VRF to associate
    port_id str
    UUID of the Connection Port where the VC is scoped to
    project_id str
    UUID of the Project where the VC is scoped to
    connection_id str
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    customer_ip str
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    customer_ipv6 str
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    description str
    Description of the Virtual Circuit resource
    md5 str
    The password that can be set for the VRF BGP peer
    metal_ip str
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    metal_ipv6 str
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    name str
    Name of the Virtual Circuit resource
    nni_vlan int
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    peer_asn int
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    speed str
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    subnet str
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    subnet_ipv6 str
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    tags Sequence[str]
    Tags attached to the virtual circuit
    virtual_circuit_id str
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    vlan_id str
    UUID of the VLAN to associate
    vrf_id str
    UUID of the VRF to associate
    portId String
    UUID of the Connection Port where the VC is scoped to
    projectId String
    UUID of the Project where the VC is scoped to
    connectionId String
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    customerIp String
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    customerIpv6 String
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    description String
    Description of the Virtual Circuit resource
    md5 String
    The password that can be set for the VRF BGP peer
    metalIp String
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    metalIpv6 String
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    name String
    Name of the Virtual Circuit resource
    nniVlan Number
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    peerAsn Number
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    speed String
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    subnet String
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    subnetIpv6 String
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    tags List<String>
    Tags attached to the virtual circuit
    virtualCircuitId String
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    vlanId String
    UUID of the VLAN to associate
    vrfId String
    UUID of the VRF to associate

    Outputs

    All input properties are implicitly available as output properties. Additionally, the VirtualCircuit resource produces the following output properties:

    Id string
    The provider-assigned unique ID for this managed resource.
    NniVnid int
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    Status string
    Status of the virtual circuit resource
    Vnid int
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    Id string
    The provider-assigned unique ID for this managed resource.
    NniVnid int
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    Status string
    Status of the virtual circuit resource
    Vnid int
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    id String
    The provider-assigned unique ID for this managed resource.
    nniVnid Integer
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    status String
    Status of the virtual circuit resource
    vnid Integer
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    id string
    The provider-assigned unique ID for this managed resource.
    nniVnid number
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    status string
    Status of the virtual circuit resource
    vnid number
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    id str
    The provider-assigned unique ID for this managed resource.
    nni_vnid int
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    status str
    Status of the virtual circuit resource
    vnid int
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    id String
    The provider-assigned unique ID for this managed resource.
    nniVnid Number
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    status String
    Status of the virtual circuit resource
    vnid Number
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/

    Look up Existing VirtualCircuit Resource

    Get an existing VirtualCircuit resource’s state with the given name, ID, and optional extra properties used to qualify the lookup.

    public static get(name: string, id: Input<ID>, state?: VirtualCircuitState, opts?: CustomResourceOptions): VirtualCircuit
    @staticmethod
    def get(resource_name: str,
            id: str,
            opts: Optional[ResourceOptions] = None,
            connection_id: Optional[str] = None,
            customer_ip: Optional[str] = None,
            customer_ipv6: Optional[str] = None,
            description: Optional[str] = None,
            md5: Optional[str] = None,
            metal_ip: Optional[str] = None,
            metal_ipv6: Optional[str] = None,
            name: Optional[str] = None,
            nni_vlan: Optional[int] = None,
            nni_vnid: Optional[int] = None,
            peer_asn: Optional[int] = None,
            port_id: Optional[str] = None,
            project_id: Optional[str] = None,
            speed: Optional[str] = None,
            status: Optional[str] = None,
            subnet: Optional[str] = None,
            subnet_ipv6: Optional[str] = None,
            tags: Optional[Sequence[str]] = None,
            virtual_circuit_id: Optional[str] = None,
            vlan_id: Optional[str] = None,
            vnid: Optional[int] = None,
            vrf_id: Optional[str] = None) -> VirtualCircuit
    func GetVirtualCircuit(ctx *Context, name string, id IDInput, state *VirtualCircuitState, opts ...ResourceOption) (*VirtualCircuit, error)
    public static VirtualCircuit Get(string name, Input<string> id, VirtualCircuitState? state, CustomResourceOptions? opts = null)
    public static VirtualCircuit get(String name, Output<String> id, VirtualCircuitState state, CustomResourceOptions options)
    Resource lookup is not supported in YAML
    name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    state
    Any extra arguments used during the lookup.
    opts
    A bag of options that control this resource's behavior.
    resource_name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    state
    Any extra arguments used during the lookup.
    opts
    A bag of options that control this resource's behavior.
    name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    state
    Any extra arguments used during the lookup.
    opts
    A bag of options that control this resource's behavior.
    name
    The unique name of the resulting resource.
    id
    The unique provider ID of the resource to lookup.
    state
    Any extra arguments used during the lookup.
    opts
    A bag of options that control this resource's behavior.
    The following state arguments are supported:
    ConnectionId string
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    CustomerIp string
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    CustomerIpv6 string
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    Description string
    Description of the Virtual Circuit resource
    Md5 string
    The password that can be set for the VRF BGP peer
    MetalIp string
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    MetalIpv6 string
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    Name string
    Name of the Virtual Circuit resource
    NniVlan int
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    NniVnid int
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    PeerAsn int
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    PortId string
    UUID of the Connection Port where the VC is scoped to
    ProjectId string
    UUID of the Project where the VC is scoped to
    Speed string
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    Status string
    Status of the virtual circuit resource
    Subnet string
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    SubnetIpv6 string
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    Tags List<string>
    Tags attached to the virtual circuit
    VirtualCircuitId string
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    VlanId string
    UUID of the VLAN to associate
    Vnid int
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    VrfId string
    UUID of the VRF to associate
    ConnectionId string
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    CustomerIp string
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    CustomerIpv6 string
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    Description string
    Description of the Virtual Circuit resource
    Md5 string
    The password that can be set for the VRF BGP peer
    MetalIp string
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    MetalIpv6 string
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    Name string
    Name of the Virtual Circuit resource
    NniVlan int
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    NniVnid int
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    PeerAsn int
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    PortId string
    UUID of the Connection Port where the VC is scoped to
    ProjectId string
    UUID of the Project where the VC is scoped to
    Speed string
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    Status string
    Status of the virtual circuit resource
    Subnet string
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    SubnetIpv6 string
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    Tags []string
    Tags attached to the virtual circuit
    VirtualCircuitId string
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    VlanId string
    UUID of the VLAN to associate
    Vnid int
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    VrfId string
    UUID of the VRF to associate
    connectionId String
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    customerIp String
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    customerIpv6 String
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    description String
    Description of the Virtual Circuit resource
    md5 String
    The password that can be set for the VRF BGP peer
    metalIp String
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    metalIpv6 String
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    name String
    Name of the Virtual Circuit resource
    nniVlan Integer
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    nniVnid Integer
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    peerAsn Integer
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    portId String
    UUID of the Connection Port where the VC is scoped to
    projectId String
    UUID of the Project where the VC is scoped to
    speed String
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    status String
    Status of the virtual circuit resource
    subnet String
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    subnetIpv6 String
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    tags List<String>
    Tags attached to the virtual circuit
    virtualCircuitId String
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    vlanId String
    UUID of the VLAN to associate
    vnid Integer
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    vrfId String
    UUID of the VRF to associate
    connectionId string
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    customerIp string
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    customerIpv6 string
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    description string
    Description of the Virtual Circuit resource
    md5 string
    The password that can be set for the VRF BGP peer
    metalIp string
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    metalIpv6 string
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    name string
    Name of the Virtual Circuit resource
    nniVlan number
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    nniVnid number
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    peerAsn number
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    portId string
    UUID of the Connection Port where the VC is scoped to
    projectId string
    UUID of the Project where the VC is scoped to
    speed string
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    status string
    Status of the virtual circuit resource
    subnet string
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    subnetIpv6 string
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    tags string[]
    Tags attached to the virtual circuit
    virtualCircuitId string
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    vlanId string
    UUID of the VLAN to associate
    vnid number
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    vrfId string
    UUID of the VRF to associate
    connection_id str
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    customer_ip str
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    customer_ipv6 str
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    description str
    Description of the Virtual Circuit resource
    md5 str
    The password that can be set for the VRF BGP peer
    metal_ip str
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    metal_ipv6 str
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    name str
    Name of the Virtual Circuit resource
    nni_vlan int
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    nni_vnid int
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    peer_asn int
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    port_id str
    UUID of the Connection Port where the VC is scoped to
    project_id str
    UUID of the Project where the VC is scoped to
    speed str
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    status str
    Status of the virtual circuit resource
    subnet str
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    subnet_ipv6 str
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    tags Sequence[str]
    Tags attached to the virtual circuit
    virtual_circuit_id str
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    vlan_id str
    UUID of the VLAN to associate
    vnid int
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    vrf_id str
    UUID of the VRF to associate
    connectionId String
    UUID of Connection where the VC is scoped to. Only used for dedicated connections
    customerIp String
    The Customer IP address which the CSR switch will peer with. Will default to the other usable IP in the subnet.
    customerIpv6 String
    The Customer IPv6 address which the CSR switch will peer with. Will default to the other usable IP in the IPv6 subnet.
    description String
    Description of the Virtual Circuit resource
    md5 String
    The password that can be set for the VRF BGP peer
    metalIp String
    The Metal IP address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the subnet.
    metalIpv6 String
    The Metal IPv6 address for the SVI (Switch Virtual Interface) of the VirtualCircuit. Will default to the first usable IP in the IPv6 subnet.
    name String
    Name of the Virtual Circuit resource
    nniVlan Number
    Equinix Metal network-to-network VLAN ID (optional when the connection has mode=tunnel)
    nniVnid Number
    Nni VLAN ID parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    peerAsn Number
    The BGP ASN of the peer. The same ASN may be the used across several VCs, but it cannot be the same as the local_asn of the VRF.
    portId String
    UUID of the Connection Port where the VC is scoped to
    projectId String
    UUID of the Project where the VC is scoped to
    speed String
    Description of the Virtual Circuit speed. This is for information purposes and is computed when the connection type is shared.
    status String
    Status of the virtual circuit resource
    subnet String
    A subnet from one of the IP blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /30 or /31. * For a /31 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /30 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    subnetIpv6 String
    A subnet from one of the IPv6 blocks associated with the VRF that we will help create an IP reservation for. Can only be either a /126 or /127. * For a /127 block, it will only have two IP addresses, which will be used for the metalip and customerip. * For a /126 block, it will have four IP addresses, but the first and last IP addresses are not usable. We will default to the first usable IP address for the metal_ip.
    tags List<String>
    Tags attached to the virtual circuit
    virtualCircuitId String
    UUID of an existing VC to configure. Used in the case of shared interconnections where the VC has already been created.
    vlanId String
    UUID of the VLAN to associate
    vnid Number
    VNID VLAN parameter, see https://deploy.equinix.com/developers/docs/metal/interconnections/introduction/
    vrfId String
    UUID of the VRF to associate