1. Packages
  2. AWS Cloud Control
  3. API Docs
  4. lightsail
  5. getAlarm

We recommend new projects start with resources from the AWS provider.

AWS Cloud Control v1.9.0 published on Monday, Nov 18, 2024 by Pulumi

aws-native.lightsail.getAlarm

Explore with Pulumi AI

aws-native logo

We recommend new projects start with resources from the AWS provider.

AWS Cloud Control v1.9.0 published on Monday, Nov 18, 2024 by Pulumi

    Resource Type definition for AWS::Lightsail::Alarm

    Using getAlarm

    Two invocation forms are available. The direct form accepts plain arguments and either blocks until the result value is available, or returns a Promise-wrapped result. The output form accepts Input-wrapped arguments and returns an Output-wrapped result.

    function getAlarm(args: GetAlarmArgs, opts?: InvokeOptions): Promise<GetAlarmResult>
    function getAlarmOutput(args: GetAlarmOutputArgs, opts?: InvokeOptions): Output<GetAlarmResult>
    def get_alarm(alarm_name: Optional[str] = None,
                  opts: Optional[InvokeOptions] = None) -> GetAlarmResult
    def get_alarm_output(alarm_name: Optional[pulumi.Input[str]] = None,
                  opts: Optional[InvokeOptions] = None) -> Output[GetAlarmResult]
    func LookupAlarm(ctx *Context, args *LookupAlarmArgs, opts ...InvokeOption) (*LookupAlarmResult, error)
    func LookupAlarmOutput(ctx *Context, args *LookupAlarmOutputArgs, opts ...InvokeOption) LookupAlarmResultOutput

    > Note: This function is named LookupAlarm in the Go SDK.

    public static class GetAlarm 
    {
        public static Task<GetAlarmResult> InvokeAsync(GetAlarmArgs args, InvokeOptions? opts = null)
        public static Output<GetAlarmResult> Invoke(GetAlarmInvokeArgs args, InvokeOptions? opts = null)
    }
    public static CompletableFuture<GetAlarmResult> getAlarm(GetAlarmArgs args, InvokeOptions options)
    // Output-based functions aren't available in Java yet
    
    fn::invoke:
      function: aws-native:lightsail:getAlarm
      arguments:
        # arguments dictionary

    The following arguments are supported:

    AlarmName string
    The name for the alarm. Specify the name of an existing alarm to update, and overwrite the previous configuration of the alarm.
    AlarmName string
    The name for the alarm. Specify the name of an existing alarm to update, and overwrite the previous configuration of the alarm.
    alarmName String
    The name for the alarm. Specify the name of an existing alarm to update, and overwrite the previous configuration of the alarm.
    alarmName string
    The name for the alarm. Specify the name of an existing alarm to update, and overwrite the previous configuration of the alarm.
    alarm_name str
    The name for the alarm. Specify the name of an existing alarm to update, and overwrite the previous configuration of the alarm.
    alarmName String
    The name for the alarm. Specify the name of an existing alarm to update, and overwrite the previous configuration of the alarm.

    getAlarm Result

    The following output properties are available:

    AlarmArn string
    The Amazon Resource Name (ARN) of the alarm.
    ComparisonOperator string
    The arithmetic operation to use when comparing the specified statistic to the threshold. The specified statistic value is used as the first operand.
    ContactProtocols List<string>
    The contact protocols to use for the alarm, such as Email, SMS (text messaging), or both.
    DatapointsToAlarm int
    The number of data points that must be not within the specified threshold to trigger the alarm. If you are setting an "M out of N" alarm, this value (datapointsToAlarm) is the M.
    EvaluationPeriods int
    The number of most recent periods over which data is compared to the specified threshold. If you are setting an "M out of N" alarm, this value (evaluationPeriods) is the N.
    NotificationEnabled bool
    Indicates whether the alarm is enabled. Notifications are enabled by default if you don't specify this parameter.
    NotificationTriggers List<string>
    The alarm states that trigger a notification.
    State string
    The current state of the alarm.
    Threshold double
    The value against which the specified statistic is compared.
    TreatMissingData string
    Sets how this alarm will handle missing data points.
    AlarmArn string
    The Amazon Resource Name (ARN) of the alarm.
    ComparisonOperator string
    The arithmetic operation to use when comparing the specified statistic to the threshold. The specified statistic value is used as the first operand.
    ContactProtocols []string
    The contact protocols to use for the alarm, such as Email, SMS (text messaging), or both.
    DatapointsToAlarm int
    The number of data points that must be not within the specified threshold to trigger the alarm. If you are setting an "M out of N" alarm, this value (datapointsToAlarm) is the M.
    EvaluationPeriods int
    The number of most recent periods over which data is compared to the specified threshold. If you are setting an "M out of N" alarm, this value (evaluationPeriods) is the N.
    NotificationEnabled bool
    Indicates whether the alarm is enabled. Notifications are enabled by default if you don't specify this parameter.
    NotificationTriggers []string
    The alarm states that trigger a notification.
    State string
    The current state of the alarm.
    Threshold float64
    The value against which the specified statistic is compared.
    TreatMissingData string
    Sets how this alarm will handle missing data points.
    alarmArn String
    The Amazon Resource Name (ARN) of the alarm.
    comparisonOperator String
    The arithmetic operation to use when comparing the specified statistic to the threshold. The specified statistic value is used as the first operand.
    contactProtocols List<String>
    The contact protocols to use for the alarm, such as Email, SMS (text messaging), or both.
    datapointsToAlarm Integer
    The number of data points that must be not within the specified threshold to trigger the alarm. If you are setting an "M out of N" alarm, this value (datapointsToAlarm) is the M.
    evaluationPeriods Integer
    The number of most recent periods over which data is compared to the specified threshold. If you are setting an "M out of N" alarm, this value (evaluationPeriods) is the N.
    notificationEnabled Boolean
    Indicates whether the alarm is enabled. Notifications are enabled by default if you don't specify this parameter.
    notificationTriggers List<String>
    The alarm states that trigger a notification.
    state String
    The current state of the alarm.
    threshold Double
    The value against which the specified statistic is compared.
    treatMissingData String
    Sets how this alarm will handle missing data points.
    alarmArn string
    The Amazon Resource Name (ARN) of the alarm.
    comparisonOperator string
    The arithmetic operation to use when comparing the specified statistic to the threshold. The specified statistic value is used as the first operand.
    contactProtocols string[]
    The contact protocols to use for the alarm, such as Email, SMS (text messaging), or both.
    datapointsToAlarm number
    The number of data points that must be not within the specified threshold to trigger the alarm. If you are setting an "M out of N" alarm, this value (datapointsToAlarm) is the M.
    evaluationPeriods number
    The number of most recent periods over which data is compared to the specified threshold. If you are setting an "M out of N" alarm, this value (evaluationPeriods) is the N.
    notificationEnabled boolean
    Indicates whether the alarm is enabled. Notifications are enabled by default if you don't specify this parameter.
    notificationTriggers string[]
    The alarm states that trigger a notification.
    state string
    The current state of the alarm.
    threshold number
    The value against which the specified statistic is compared.
    treatMissingData string
    Sets how this alarm will handle missing data points.
    alarm_arn str
    The Amazon Resource Name (ARN) of the alarm.
    comparison_operator str
    The arithmetic operation to use when comparing the specified statistic to the threshold. The specified statistic value is used as the first operand.
    contact_protocols Sequence[str]
    The contact protocols to use for the alarm, such as Email, SMS (text messaging), or both.
    datapoints_to_alarm int
    The number of data points that must be not within the specified threshold to trigger the alarm. If you are setting an "M out of N" alarm, this value (datapointsToAlarm) is the M.
    evaluation_periods int
    The number of most recent periods over which data is compared to the specified threshold. If you are setting an "M out of N" alarm, this value (evaluationPeriods) is the N.
    notification_enabled bool
    Indicates whether the alarm is enabled. Notifications are enabled by default if you don't specify this parameter.
    notification_triggers Sequence[str]
    The alarm states that trigger a notification.
    state str
    The current state of the alarm.
    threshold float
    The value against which the specified statistic is compared.
    treat_missing_data str
    Sets how this alarm will handle missing data points.
    alarmArn String
    The Amazon Resource Name (ARN) of the alarm.
    comparisonOperator String
    The arithmetic operation to use when comparing the specified statistic to the threshold. The specified statistic value is used as the first operand.
    contactProtocols List<String>
    The contact protocols to use for the alarm, such as Email, SMS (text messaging), or both.
    datapointsToAlarm Number
    The number of data points that must be not within the specified threshold to trigger the alarm. If you are setting an "M out of N" alarm, this value (datapointsToAlarm) is the M.
    evaluationPeriods Number
    The number of most recent periods over which data is compared to the specified threshold. If you are setting an "M out of N" alarm, this value (evaluationPeriods) is the N.
    notificationEnabled Boolean
    Indicates whether the alarm is enabled. Notifications are enabled by default if you don't specify this parameter.
    notificationTriggers List<String>
    The alarm states that trigger a notification.
    state String
    The current state of the alarm.
    threshold Number
    The value against which the specified statistic is compared.
    treatMissingData String
    Sets how this alarm will handle missing data points.

    Package Details

    Repository
    AWS Native pulumi/pulumi-aws-native
    License
    Apache-2.0
    aws-native logo

    We recommend new projects start with resources from the AWS provider.

    AWS Cloud Control v1.9.0 published on Monday, Nov 18, 2024 by Pulumi